Evaluation of detection performance of urinary vanilmandelic acid on automatic biochemical analyzer
	    		
		   		
		   			
		   		
	    	
    	 
    	10.7687/j.issn1003-8868.2018.04.061
   		
        
        	
        		- VernacularTitle:使用全自动生化分析仪检测尿香草扁桃酸的性能评价
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Chen-Geng LIU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Ting HAO
			        		
			        		;
		        		
		        		
		        		
			        		Yong CHENG
			        		
			        		;
		        		
		        		
		        		
			        		Li-Chun ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Ping-Ping ZHAO
			        		
			        		;
		        		
		        		
		        		
			        		Hong-Yan WANG
			        		
			        		;
		        		
		        		
		        		
			        		Pei-Chang WANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 首都医科大学宣武医院检验科
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		vanilmandelic acid;
			        		
			        		
			        		
				        		automatic biochemical analyzer;
			        		
			        		
			        		
				        		analyzer method;
			        		
			        		
			        		
				        		manual method;
			        		
			        		
			        		
				        		performance verification
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Medical Equipment Journal
	            		
	            		 2018;39(4):61-63,88
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To evaluate the automatic biochemical analyzer when used to detect urinary vanilmandelic acid (VMA), and to compare it with manual method. Methods The automatic biochemical analyzer using homogenous enzyme immunoassay technology was compared with the manual method on accuracy, precision, linear range, recovery rate, anti-interference capability and etc when used to detect VMA.The comparison was also carried out on positive rate and etc when the two methods were used to test the urine specimens of the healthy subjects and suspected patients of hypertension, hyperthyroidism and hypothyroidism. Results The two methods both had the results on accuracy, precision, linear range, recovery rate, anti-interference capability meet the requirements described in the instruction of reagent kit, while the analyzer gained advantages over the manual method.The positive rates by the two methods for testing urine specimens were similar,while the analyzer behaved better in diagnosing the patient with critical value.Conclusion The analyzer proves better than the manual method when used to detect VMA,and thus is worthy promoting in clinical trial.