Review of high-resolution peripheral quantitative computed tomography for the assessment of bone microstructure and strength.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.7507/1001-5515.201707068
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jianxiong MA
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Jie ZHAO
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Weiwei HE
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Mingjie KUANG
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Hengting CHEN
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Lukai ZHANG
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Lei SUN
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Yuhong CUI
			        		
			        		
			        		
			        			3
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Xinlong MA
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Ying WANG
			        		
			        		
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. School of Mechanical Engineering, Tianjin University, Tianjin 300072, P.R.China;Orthopaedics Institute, Tianjin Hospital, Tianjin 300211, P.R.China;Orthopaedics Institute, Tianjin University Tianjin Hospital, Tianjin 300211, P.R.China.
			        		
			        			2. Orthopaedics Institute, Tianjin Hospital, Tianjin 300211, P.R.China;Orthopaedics Institute, Tianjin University Tianjin Hospital, Tianjin 300211, P.R.China.
			        		
			        			3. School of Mechanical Engineering, Tianjin University, Tianjin 300072, P.R.China.
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		bone density;
			        		
			        		
			        		
				        		bone microstructure;
			        		
			        		
			        		
				        		bone strength;
			        		
			        		
			        		
				        		high-resolution peripheral quantitative computed tomography
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Biomedical Engineering
	            		
	            		 2018;35(3):468-474
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Trabecular microstructure is an important factor in determining bone strength and physiological function. Normal X-ray and computed tomography (CT) cannot accurately reflect the microstructure of trabecular bone. High-resolution peripheral quantitative computed tomography (HR-pQCT) is a new imaging technique in recent years. It can qualitatively and quantitatively measure the three-dimensional microstructure and volume bone mineral density of trabecular bone . It has high precision and relative low dose of radiation. This new imaging tool is helpful for us to understand the trabecular microstructure more deeply. The finite element analysis of HR-pQCT data can be used to predict the bone strength accurately. We can assess the risk of osteoporosis and fracture with three-dimensional reconstructed images and trabecular microstructure parameters. In this review, we summarize the technical flow, data parameters and clinical application of HR-pQCT in order to provide some reference for the popularization and extensive application of HR-pQCT.