Application of dual-source CT dual-energy scanning fusion 3D reconstruction in gastric cancer and lymph nodes
	    		
		   		
		   			
		   		
	    	
    	 
    	10.11904/j.issn.1002-3070.2017.05.007
   		
        
        	
        		- VernacularTitle:双源CT双能量扫描融合三维重建技术在诊断胃癌及淋巴结中应用的研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Zhiyun JIANG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Pengfei LI
			        		
			        		;
		        		
		        		
		        		
			        		Lin SUI
			        		
			        		;
		        		
		        		
		        		
			        		Naijian SHANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 哈尔滨医科大学附属肿瘤医院
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Dual-energy of dual-source CT scanning;
			        		
			        		
			        		
				        		Three-dimensional reconstruction;
			        		
			        		
			        		
				        		IC;
			        		
			        		
			        		
				        		NIC;
			        		
			        		
			        		
				        		The slope of spectrum curve
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Practical Oncology Journal
	            		
	            		 2017;31(5):425-430
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective The objective of this study was to determine the lesion range between gastric cancer lesions and normal gastric wall,improve the early diagnosis of gastric cancer rate,distinguish between me-tastatic lymph nodes and non-metastatic lymph nodes,and accurate N staging by dual-source CT double-en-ergy enhanced scan parameters.Methods The dual energy enhanced scan of patients with preoperative gastric cancer was performed by Siemens Somatom Definition Flash dual-source CT.The collected data were analyzed by Syngo.Via software and reconstructed three-dimensionally to obtain the absolute iodine of gastric cancer,nor-mal gastric wall,metastatic lymph node and non-metastatic lymph node value,standardized iodine value and vir-tual single energy spectrum curve of the slope to combine with postoperative pathological results.The use of statis-tical methods was to determine the difference between the post-and preoperation.Results The absolute iodine values(IC)were(3.329±0.812)g/L in the gastric cancer lesion and(64.006±17.450)% for the standard io-dine values(NIC).The slope of the virtual single energy spectrum curve was-2.916±1.3227,IC(1.563±0.708)g/L in the normal gastric wall.The NIC were(37.122±16.267)%and-1.621±1.4028 for the slope of the virtual single energy spectrum curve.They were significantly statistical difference(P<0.05).The IC of meta-static lymph nodes were(2.968±0.547)g/L,(63.597±14.633)% for the NIC and(-2.532±0.753)for the slope of the virtual single energy spectrum curve.The IC of non-metastatic lymph nodes were(1.465±0.408)g/L,(35.240±14.357)%for the NIC and(-1.378±0.726)for the slope of the virtual single energy spectrum curve.They also had significantly statistical difference(P<0.05).Conclusion Dual-source CT dual-energy scan combined with three-dimensional reconstruction technique can help to determine the lesion range,improve the diagnostic rate of early gastric cancer,distinguish between metastatic and non-metastatic lymph nodes,and improve the accuracy of N staging.