Determination of Content and Related Substances of Flibanserin by HPLC-DAD
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:HPLC-DAD法测定氟班色林原料药的含量及有关物质
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hongfang TIAN
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Hua WANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. 北京中医医院顺义医院 北京101300
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Flibanserin;
			        		
			        		
			        		
				        		HPLC;
			        		
			        		
			        		
				        		Determination;
			        		
			        		
			        		
				        		Related substance
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacist
	            		
	            		 2017;20(10):1777-1780
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To establish an HPLC method for the determination of flibanserin and its related substances. Methods: A Phenomenex Luna C18 column(150 mm × 4. 60 mm, 5 μm) was used, the mobile phase consisted of 0. 02 mol·L-1 potassium di-hydrogen phosphate solution (pH was adjusted to 6. 0 by sodium hydroxide)-methanol and acetonitrile (4 :1), the flow rate was 1. 0 ml·min-1 , the column temperature was 30℃, the detection wavelength was 260 nm, and the injection volume was 10 μl. Results:Flibanserin and all the related compounds could be well separated. The linear range was 20-500 μg·ml-1(r=0. 9998), the average recovery was 100. 0%(RSD=0. 90%,n=9). The content of the main component in 4 batches of samples was 99. 6%, 99. 8%, 100. 4% and 99. 4%, respectively. The single impurity limit was set at 0. 1% and the limit of total impurities was set at 0. 5%. Con-clusion:The method is specific and accurate, which can be applied in the determination of content and related substances of fliban-serin.