Observation of Ex - press miniature implantation with deep sclerectomy surgery for refractory glaucoma
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3980/j.issn.1672-5123.2016.6.39
   		
        
        	
        		- VernacularTitle:Ex-press微型引流器植入联合深层巩膜切除术治疗难治性青光眼
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Yu, DI
			        		
			        		;
		        		
		        		
		        		
			        		Qing-Zhu, NIE
			        		
			        		;
		        		
		        		
		        		
			        		Dian-Wen, GAO
			        		
			        		;
		        		
		        		
		        		
			        		Xiao-Long, CHEN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Ex- Press miniature implantation;
			        		
			        		
			        		
				        		deep sclerectomy;
			        		
			        		
			        		
				        		refractory glaucoma;
			        		
			        		
			        		
				        		intraocular pressure
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			International Eye Science
	            		
	            		 2016;16(6):1150-1152
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	?AIM: To evaluate the effect for refractory glaucoma by using Ex - Press miniature implantation with deep sclerectomy.?METHODS: Thirty eyes in 24 patients with refractory glaucoma were treated by Ex- Press miniature ( P50 ) implantation with deep sclerectomy. The patients’ symptom, intraocular pressure ( IOP ) , visual acuity and complications were analyzed in a 12mo follow-up period.?RESULTS: During the follow-up period, all patients’ ocular pain was reduced. The mean IOP before operation and at the last follow-up time were 51. 15 ± 2. 60mmHg (1kPa=7. 5mmHg) and 15. 11 ± 2. 51mmHg, respectively, there was significant difference (P<0. 05). Postoperative visual acuity was improved in 8 eyes, had no significant change in 22 eyes. After operation, hyphema of anterior chamber appeared in 2 eye ( 7%) , which were obsorbed after 1wk.? CONCLUSION: Ex - Press miniature implantation combined with deep sclerectomy surgery is a relatively effective and safe treatment for the patients with refractory glaucoma. This method can significantly degrade the IOP, lessen ocular pain and reduce the complications risk.