Real-time three-dimensional color Doppler flow imaging: an improved technique for quantitative analysis of aortic regurgitation.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qing, LU
			        		
			        		;
		        		
		        		
		        		
			        		Xiatian, LIU
			        		
			        		;
		        		
		        		
		        		
			        		Mingxing, XIE
			        		
			        		;
		        		
		        		
		        		
			        		Xinfang, WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jing, WANG
			        		
			        		;
		        		
		        		
		        		
			        		Lei, ZHUANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Aortic Valve Insufficiency/*ultrasonography;
				        		
			        		
				        		
					        		Echocardiography, Doppler, Color;
				        		
			        		
				        		
					        		Echocardiography, Three-Dimensional
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:
	            		
	            			Journal of Huazhong University of Science and Technology (Medical Sciences)
	            		
	            		 2006;26(1):148-52
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r = 0.93, Y = 0.89X + 3.9, SEE = 8.6 mL, P < 0.001); the mean (SD) difference between the two methods was--1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r = 0.88, Y = 0.71X + 14.8, SEE = 6.4%, P < 0.001); the mean (SD) difference between the two methods was--1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF.