Determination of dexamethasone in human plasma by solid phase extraction with ultra performance liquid chromatography-tandem mass spectrometer
	    		
		   		
		   			
		   		
	    	
    	 
    	10.13618/j.issn.1001-5728.2017.03.017
   		
        
        	
        		- VernacularTitle:固相萃取-液相色谱-质谱法检验人全血中的地塞米松
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Yujing LUAN
			        		
			        		;
		        		
		        		
		        		
			        		Ruihua WANG
			        		
			        		;
		        		
		        		
		        		
			        		Ying DONG
			        		
			        		;
		        		
		        		
		        		
			        		Leiping ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Zhongshan YU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		forensic toxicological analysis;
			        		
			        		
			        		
				        		solid phase extraction;
			        		
			        		
			        		
				        		UPLC-MS/MS;
			        		
			        		
			        		
				        		dexamethasone
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Forensic Medicine
	            		
	            		 2017;32(3):297-299
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To develop the analytical method to determine the content of dexamethasone in human plasma by solid phase extraction with ultra performance liquid chromatography-tandem mass spectrometer. Methods The human plasma was extracted with a solid phase extraction(SPE) and determined by UPLC-MS/MS. LC-MS/MS was performed in ESI source with MRM mode for quantification. Results The lowest detectable limit was 0.05ng/mL, the linear range was 1~100ng/mL. The absolute recovery was more than 78.1%. The intra- and inter day precision was within 15% at three concentrations. Conclusion Since the procedure proved to be simple, quick and effective, it could be used for the determination of dexamethasone in human plasma.