Accuracy Assessment of Type III Portable Monitor of Sleep Apnea for In-hospital Patients With Cardiovascular Disease
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1000-3614.2017.05.015
   		
        
        	
        		- VernacularTitle:Ⅲ级睡眠呼吸监测设备在住院心血管疾病患者中监测的准确性评价
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Ling WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jiawei ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Bixia HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Rui WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jianfang LUO
			        		
			        		;
		        		
		        		
		        		
			        		Jiyan CHEN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Sleep apnea Cardiovascular disease Syndrom;
			        		
			        		
			        		
				        		Sleep apnea monitoring
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Circulation Journal
	            		
	            		 2017;32(5):485-488
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective: To assess the accuracy and application value of type III portable monitor (III PM) of sleep apnea (SA) for in-hospital patients with cardiovascular disease (CVD). Methods: A total of 101 CVD patients received sleep apnea monitoring by both type II polysomnography ( II PSG) and III PM were enrolled to compare the apnea-hypopnea index (AHI) measured by 2 instruments. AHI was assigned into 4 grades: Normal (AHI<5), Mild grade (5≤AHI<15), Moderate grade (15≤AHI<30) and Severe grade (AHI≥30). Kendall correlation coefficient and Kappa value were calculated, pair wise t test was conducted in relevant patients. Results: II PSG and III PM measured AHI were (18.0±16.6) events/h and (18.6±17.4) events/h, P>0.05. Kendall correlation coefficient for 4 AHI grades was 0.701, P<0.01 which assumed strong correlation; Kappa value of consistency was 0.493, P<0.01 which assumed medium strong correlation. Using AHI≥15 as cut-off point, Kappa coefficient for the consistency between II PSG and III PM was 0.679, P<0.05, which meant high consistency. Taking II PSG as standard and AHI≥15 as cut-off point, the AUC of III PM measured AHI was 0.918 with the specificity at 80.4% and sensitivity at 87.3%. The best diagnosing cut-off value of III PM was AHI=15.70, at this point, the maximum Youden's index was obtained as 0.695. Conclusion: Using AHI≥15 as standard, III PM and II PSG had the favorable consistency and accuracy for monitoring the severity of SA for in-hospital patients with cardiovascular disease. AHI=15.7 was the best cut-off point of III PM in diagnosing moderate and severe SA in relevant patients.