Dosimetric Comparison of Inverse Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Non-Ssmall Cell Lung Cancer
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1005-202X.2010.02.002
   		
        
        	
        		- VernacularTitle:逆向3D-CRT与IMRT计划设计方法在非小细胞肺癌放疗中的剂量学比较
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Fuli ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Weidong XU
			        		
			        		;
		        		
		        		
		        		
			        		Junmao GAO
			        		
			        		;
		        		
		        		
		        		
			        		Jianping CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Ping WANG
			        		
			        		;
		        		
		        		
		        		
			        		Mingmin ZHENG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		inverse three-dimensional conformal radiotherapy;
			        		
			        		
			        		
				        		intensity modulated radiotherapy;
			        		
			        		
			        		
				        		non-small cell lung cancer
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Medical Physics
	            		
	            		 2010;27(2):1704-1707,1720
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective: To compare inverse three-dimensional conformal radiotherapy (Inv 3D-CRT) and intensity modulated ra-diotherapy (IMRT) for non-small cell lung cancer. Methods: For a cohort of 10 patients, Inv 3D-CRT and three groups of IMRT plannings were designed for per patient. The prescribed dose was 60 Gy/2 Gy/30f, 95% of the planning target volume received this dose. Dose was computed with a commercially available TPS using convolution/superposition (CS) algorithm. Plans were compared according to the PTV_(95)V_(20) ratio (PTV_(95)V_(20)) and D_(max)-D_(min). Results: Compared with Inv 3D-CRT, the PTV_(95)V_(20) ratio of three groups of IMRT increased by 1.08 (P = 0.014), 0.72 (P = 0.089) and 0.42 (P = 0.318), respectively. Conclusions: For NSCLC, IMRT can reduce the dose to the lungs compared with inverse 3D-CRT by improving the conformity of the plan and is worth spreading in clinical work.