Determination of Zolpidemtartrate in Plasma by SPE-HPLC
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:固相萃取结合高效液相色谱法测定人血浆中酒石酸唑吡坦的浓度
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Junping GUO
			        		
			        		;
		        		
		        		
		        		
			        		Anjin ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Minfang HU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		HPLC;
			        		
			        		
			        		
				        		Solid-phase extraction;
			        		
			        		
			        		
				        		Zolpidemtartrate;
			        		
			        		
			        		
				        		Plasma concentration
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacist
	            		
	            		 2016;19(4):788-789,790
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To establish a method for the determination of zolpidemtartrate in human plasma by SPE-HPLC. Methods:The samples were extracted by solid phase with a Hypersil BDS C18 column and determined by an internal standard method. The mobile phase was methanol:acetonitrile:water (45 ∶45 ∶110), the flow rate was 1. 0 ml·min-1, the column temperature was 35℃, and the detection wavelength was 254nm. Results:The linear relationship of zolpidemtartrate was within the range of 0. 511 5-4. 092 0 μg· ml-1 . The relative recovery was greater than 90%. The intra-and inter-day RSDs were all less than 10%. Conclusion:The method is quite simple, quick and accurate with little interference, which is suitable for the clinical determination of zolpidemtartrate.