Establishment of biology reference interval of NSE in cerebrospinal fluid
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1673-4130.2015.10.001
   		
        
        	
        		- VernacularTitle:脑脊液神经元性烯醇化酶生物参考区间的建立
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Yanfei CAO
			        		
			        		;
		        		
		        		
		        		
			        		Gang CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Lina ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiupeng DONG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaonan KOU
			        		
			        		;
		        		
		        		
		        		
			        		Ying CUI
			        		
			        		;
		        		
		        		
		        		
			        		Xiuhua CAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		biological reference interval;
			        		
			        		
			        		
				        		clinical medical laboratory;
			        		
			        		
			        		
				        		cerebrospinal fluid;
			        		
			        		
			        		
				        		neuron specific enolase
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			International Journal of Laboratory Medicine
	            		
	            		 2015;(10):1321-1322,1324
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To establish the reference intervals of neuron specific enolase (NSE) in tumor markers in cerebrospinal fluid .Methods According to National Committee for Clinical Laboratory Standards document C 28‐A2 ,120 samples were collected to establish reference intervals .Then ,the established intervals were evaluated according to China National Accreditation Service for Conformity Assessment document CL38 :2012 .Results The biological reference interval of NSE in cerebrospinal fluid was 0-3 .14 ng/mL .There was no significant correlation between cerebrospinal fluid NSE level and age ,sex (P> 0 .05) .Conclusion Method used in this study could be ensured reliable ,accurate ,scientific and practical ,desirable for clinical requirement and with great poten‐tial for clinical application .