Evaluation for application of remote electrocardiogram recorder in community residents
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1008-0074.2012.02.08
   		
        
        	
        		- VernacularTitle:远程心电记录仪在社区中应用的评价
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jinjun LIANG
			        		
			        		;
		        		
		        		
		        		
			        		He HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Di LIANG
			        		
			        		;
		        		
		        		
		        		
			        		Yang FAN
			        		
			        		;
		        		
		        		
		        		
			        		Shaobo SHI
			        		
			        		;
		        		
		        		
		        		
			        		Fang CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Mingwei BAO
			        		
			        		;
		        		
		        		
		        		
			        		Bo YANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Electrocardiography;
			        		
			        		
			        		
				        		Telemedicine;
			        		
			        		
			        		
				        		Arrhythmia
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of cardiovascular Rehabilitation Medicine
	            		
	            		 2012;21(2):196-200
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective: To evaluate the value of clinical application of Heart of the City type TJH-03A remote electrocardiogram recorder (remote ECG). Methods: A total of 1 014 community residents from Wuhan received ECG examination by Heart of the City type TJH-03A remote ECG recorder. Clinical and ECG data of all subjects were collected and analyzed. Results: There were 359 (35.40%) cases with normal ECG and 655 (64.60%) cases with abnormal ECG, after remote ECG examination . There were 581 cases had a variety of arrhythmia in 655 cases with abnormal ECG, so there were 828 cases times with abnormal ECG, in which there were (1)320 cases times  (38.65%) with repolarization abnormality,(2)98 cases times(11.84%) with sinus bradycardia, (3)98 cases times (11.84%)with myocardial ischemia,(4)78 cases times (9.42%)with conduction block,(5)56  cases times(6.76%) with ventricular hypertrophy and high voltage,(6)43 cases times(5.19%) with atrial premature beats(7)37 cases times (4.47%)with atrial fibrillation,(8)35 cases times (4.23%)with sinus tachycardia,(9)24 cases times (2.90%)with ventricular premature beats, (10)19 cases times (2.29%)with suspected myocardial infarction according to ECG abnormality rate order. In addition, there were 5 cases times with QT interval prolongation, and abnormal ECG with abnormality rate ≤3 cases times: atrial tachycardia, atrial flutter, supraventricular tachycardia, ventricular tachycardia, Brugada wave, dextrocardia. Conclusion: Heart of the City type TJH-03A remote electrocardiogram recorder is convenient to use, it can perform remote electrocardiogram record, and find a variety of arrhythmias. It’s important for ECG diagnosis, especially for diagnosis of arrhythmias.
				        	
				        
				    
			    
 
	        
	        
	        	- Full text:P020120515703763281462.doc