Determination of Tetrahydropalmatione in FuLe Granules by HPLC
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:高效液相色谱法测定妇乐颗粒中延胡索乙素的含量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jianying ZHAO
			        		
			        		;
		        		
		        		
		        		
			        		Weiyuan BAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		FuLe granules;
			        		
			        		
			        		
				        		Tetrahydropalmatione;
			        		
			        		
			        		
				        		HPLC;
			        		
			        		
			        		
				        		Content determination
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Traditional Chinese Drug Research & Clinical Pharmacology
	            		
	            		 1993;0(02):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To establish a method for the determination of tetrah yd ropalmatione in FuLe granules. Methods A HPLC method was used with DiamonsilTM C 18(250? 4.6 mn, 5 ? m) column and a mobile phase of methanol- 0.1 % phospho ric acid solution (adjusted the pH to 6.0 with triethylamine)(60 ∶ 40). Flow ra te was 1.0 mL/min, column tem perature 35 ℃ , the detection wavelength at 280nm and sample loop volume bei ng 20 ? L. Results The calibration curve was linear within the range of 0.102 ~ 1.632 ? g of tetrahydropalmatione, the average recovery was 98.78 % (RSD=2 .75 % ).Conclusion The method is simple and accurate.It can be used for the q uality control of Fule granules.