Determination of Endotoxin in Chuan Hu Ning Iinjection with Kinetic Turbidimetry Limulus Test
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:动态比浊法测定注射用穿琥宁细菌内毒素的含量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qiuqiong LIU
			        		
			        		;
		        		
		        		
		        		
			        		Haiyan LAO
			        		
			        		;
		        		
		        		
		        		
			        		Qiuxiao LIN
			        		
			        		;
		        		
		        		
		        		
			        		Yang OU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Dynamic Turbidimetry Limulus Test;
			        		
			        		
			        		
				        		@Chuan Hu Ning Injection/chemistry;
			        		
			        		
			        		
				        		@Bacterial Endotoxin
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Traditional Chinese Drug Research & Clinical Pharmacology
	            		
	            		 2000;0(06):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective: The dynamic turbidimetry Limulus test was used to assay endotoxin content in Chuan Hu Ning injection. Methods: When the standardized endotoxin added in Chuan Hu Ning injection sample (Lot.No.000409) and in its 40-fold dilution, 80-fold dilution, 120-fold dilution and 200-fold dilution , the recovery was 0 %, 21.18 %, 76.69 %, 101.1 %and 117.8 %and as the standardized endotoxin added in the three batches of 200-fold dilution of Chuan Hu Ning injection (Lot.No.000408?000409?001023), the recovery was 110.5 %, 124.4 %and 87.98 %. Results: As standardized endotoxin concentration being 5.00, 0.500, 0.0500Eu/mL , the 200-fold dilution of Chuan Hu Ning injection is effective to eliminate the interference in the test. Conclusion: The dynamic turbidimetry Limulus test provides a new way for the determination of endotoxin in Chuan Hu Ning injection.