Application study on LC-ESI--MS/MS determination of inosine in human plasma
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1671-8348.2014.03.020
   		
        
        	
        		- VernacularTitle:LC-ESI-M S/M S方法测定人血浆肌苷的应用研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hongbo WANG
			        		
			        		;
		        		
		        		
		        		
			        		Mengliang ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Yunhui ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Yan YANG
			        		
			        		;
		        		
		        		
		        		
			        		Baochang ZHANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		inosine;
			        		
			        		
			        		
				        		inosine pranobex;
			        		
			        		
			        		
				        		liquid chromatography-tandem mass spectrometry;
			        		
			        		
			        		
				        		plasma;
			        		
			        		
			        		
				        		pharmacokinetics
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chongqing Medicine
	            		
	            		 2014;(3):311-313,316
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To develop a LC-MS/MS method for the determination of inosine in human plasma and to apply it in the isoprinosine pharmacokinetic researches .Methods With adefovir as the internal standard ,methanol -10 mmol/L ammonium ace-tate(15 :85 ,v/v) was adopted as the mobile phase .The chromatographic column was the Agilent SB-C18 column(5 μm ,150 mm × 4 .6 mm I .D .) .Electrospray ionization(ESI) source was applied and the detection was conducted by the multiple-reaction monito-ring(MRM) mode .The ion reactions for the quantitative analysis were m/z 135 .0-267 .3(inosine) and m/z 134 .1-272 .0(adefo-vir) .Results The linear range of plasma inosine was 10-3 000 ng/mL .The lower detection limit was 10 ng/mL .The inter-and in-tra-day precisions(RSD) were less than 5% .The average recovery rate was above 90% without the matrix effect .Conclusion This method has the strong specificity ,convenience in treating the sample and high sensitivity ,and is suitable for the inosine pharmacokinetic re-searches .