Storage Characteristics and Disinfection Effect of Electrolyzed-oxidizing Water
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:酸性氧化电位水保存后的特性及消毒效果
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Weimin CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Xiangan XU
			        		
			        		;
		        		
		        		
		        		
			        		Xianming XIAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Disinfection;
			        		
			        		
			        		
				        		Electrolyzed-oxidizing water;
			        		
			        		
			        		
				        		Storage
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Environment and Health
	            		
	            		 1992;0(05):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective The aim of the paper is to investigate the alteration of the physical-chemical properties and disinfection effect of electrolyzed-oxidizing water during storage, and to provide theory support for its application. Methods A typical electrolyzed-oxidizing water was stored under a closed and light condition for 66 days and its physical-chemical parameters and disinfection effect were measured at fixed periods. Results The results showed that the chlorine loss of the electrolyzed-oxidizing water was quite fast and reached 50% and 100% after 10 days and 66 days of storage period respectively, the pH value was quite stable, from 2.5 to 2.47. The oxidation-reduction potential(ORP) of the water decreased slowly only from 1 146 mV to 1 100 mV within 45 day, but decreased rapidly after 45 days of storage. The results also showed that the inactivation of Bacillus subtilis var niger spores by the electrolyzed-oxidizing water also decreased rapidly after one week of storage,from 100%(the first week) to less than 90%(after 10 days). Conclusion The electrolyzed-oxidizing water can keep its strong disinfection effect after 7-10 days of storage. It was believed that the chlorine loss from the electrolyzed-oxidizing water was the main reason for the decrease of its disinfection effect during storage.