Formulation Design and Content Determination of Thermosensitive Secnidazole Hydrogels
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:塞克硝唑温敏性水凝胶的处方设计与含量测定
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xianling SHEN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Secnidazole;
			        		
			        		
			        		
				        		Thermosenstive hydrogels;
			        		
			        		
			        		
				        		Orthogonal design;
			        		
			        		
			        		
				        		Poloxamer;
			        		
			        		
			        		
				        		Content determination
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacy
	            		
	            		 2001;0(09):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	OBJECTIVE:To select the optimal formulation of thermosensitive secnidazole hydrogels and establish its determination method. METHODS:Formulation was optimized by orthogonal design with the content of poloxamer P407/P188(A),ethanol (B)and sodium alginate(C)as factors and with secnidazole as index. The content of secnidazole in preparation was determined by UV spectrometry at detection wavelength of 277 nm. RESULTS:The optimal formulation was as follows:A of 15 g/15 g,B of 20 mL and C of 0.6 g. The linear range of secnidazole was 4.618~46.18 mg?L-(1r=0.999 8)with an average recovery of 98.27%. The RSD of intra-day and inter-day were both lower than 1.8% and 2.1% respectively. CONCLUSIONS:The formulation is reasonable and the process was reliable and controllable in quality.