Extraction of DNA from Corydalis saxicola:Comparison among Different Extraction Methods
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:岩黄连总DNA不同提取方法的比较
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qichun HUANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Coryaalis saxicola;
			        		
			        		
			        		
				        		Palmityl trimethyl ammonium bromide;
			        		
			        		
			        		
				        		Guanidinium isothiocyanate;
			        		
			        		
			        		
				        		Enzyme-added detergent;
			        		
			        		
			        		
				        		Adsorption column;
			        		
			        		
			        		
				        		DNA;
			        		
			        		
			        		
				        		Extraction
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacy
	            		
	            		 2007;0(30):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	OBJECTIVE:To draw a comparison among four extraction methods of total DNA from Corydalis saxicola in order to get high quality DNA sample.METHODS:The total DNA was extracted by palmityl trimethyl ammonium bromide method,enzyme-added detergent method,guanidinium isothiocyanate method,inertmacromolecular adsorptive column method,respectively.The purity(defined as RA260/A280)and the yield of the total DNA were determined.RESULTS:The RA260/A280 values of the DNA samples extracted by 4 methods were 1.832 9,1.699 2,1.812 2 and 1.813 6,respectively;and the extraction rates were 140.20 ?g?g-1,69.56 ?g?g-1,132.50 ?g?g-1 and 143.12 ?g?g-1,respectively.CONCLUSION:DNA samples extracted in 4 methods were all of high quality.The yield of DNA sample in enzyme-added extraction method was lower,while the guanidinium isothiocyanate method and the adsorption column method were rapid and simple and they are suitable for the test of samples of small size.