Experimental Study on Monitoring Extremital Blood Circulation in Rabbits with Replanted Limb by Na~(99m)TcO_4 Trace Imaging
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:核素显像监测断肢再植术后血运的实验研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Changhui XIE
			        		
			        		;
		        		
		        		
		        		
			        		Zhihai MA
			        		
			        		;
		        		
		        		
		        		
			        		Shaojie DENG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Organ transplantation,limb,replantation;
			        		
			        		
			        		
				        		Vascular crisis;
			        		
			        		
			        		
				        		Trace;
			        		
			        		
			        		
				        		Na~(99m)TcO_4, Radionuclide imaging
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Chinese Physician
	            		
	            		 2001;0(08):-
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To explore feasibility of monitoring the extremital arterial blood supply and venous blood circulation in rabbits with replanted limb by Na~(99m)TcO_4 trace imaging(TTI). Methods TTI was performed on 6 normal control rabbits and 30 rabbits with replanted limb at 24~36h after replantation. The radioactivity uptake ratio of replanted limb/normal limb(T/NT) was analyzed. Imaging was classified into ?,Ⅰ,Ⅱand Ⅲ scales according to the accumulation amount of extremital radionuclide. Then an exploratory operation was performed on each rabbit. Results Rabbits with ?,Ⅰ,Ⅱand Ⅳ scales had 8,6,15(including 6 normal control rabbits),and 7 animals, respectively, and their T/NT were 0.178?0.072, 0.461?0.046, 0.816?0.074, 1.14?0.086(P1.05) may serve as a qualitative and semiquantitative diagnostic standard for venous blood circulation block. Conclusion TTI was feasible in monitoring the extremital arterial blood supply and venous blood circulation in patients with replanted limb(finger).