Fluorescence labeling method for evaluating the efficacy of hospital environment cleaning
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1671-9638.2017.01.020
   		
        
        	
        		- VernacularTitle:荧光标记法评价医院环境卫生清洁效果
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xuelian BIAN
			        		
			        		;
		        		
		        		
		        		
			        		Shifang YU
			        		
			        		;
		        		
		        		
		        		
			        		Chunfen XU
			        		
			        		;
		        		
		        		
		        		
			        		Zhengqi YU
			        		
			        		;
		        		
		        		
		        		
			        		Chenggang CAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		hospital;
			        		
			        		
			        		
				        		environment;
			        		
			        		
			        		
				        		clean;
			        		
			        		
			        		
				        		objective evaluation;
			        		
			        		
			        		
				        		fluorescence labeling;
			        		
			        		
			        		
				        		clearance rate
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Infection Control
	            		
	            		 2017;16(1):84-86
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To evaluate the effectiveness of hospital environmental cleaning practice by fluorescence labeling method.Methods From January to February 2015,312 ward rooms in 7 hospitals were chosen,high touch object surface were labeled with fluorescence,after object surface being cleaned by cleaners,clearance rates of fluorescence labeling were calculated (as baseline survey data),training and on-site guidance for cleaners were performed(intervention measures),fluorescence labeling clearance effect before and after intervention was compared.Results A total of 110 ward rooms were performed baseline survey,the fluorescence labeling clearance rate of 2 856 touched clean surface was only 50.81%,the quantitative evaluation value was 45.70;after intervention,202 rooms were surveyed,fluorescence labeling clearance rate of 3 992 touched clean surface enhanced to 79.23 %,the quantitative evaluation value was 76.30;there was significant difference in fluorescence labeling clearance rate between before and after intervention (x2 =612.14,P<0.05).In the baseline survey,the clearance rates of fluorescence labeling on touched surface of medical instruments,hospital beds,and toilets were 46.07%,37.80%,and 25.20% respectively;after intervention,the clearance rates were 80.59%,75.90%,and 51.70%,respectively.After intervention,fluorescence labeling clearance rates of beepers,toilet seat covers,toilet electrical switches,and chairs were low,the clearance rates of these touched surface in baseline survey were< 30%,after intervention were 47.03 %-68.32%;the clearance rates of other high touch surface were all>75 %.Conclusion Fluorescence labeling method can directly reflect the operation quality of cleaners,and improve the cleanliness of ward environment,it is a simple,inexpensive and objective globally popular method for evaluating hospital environment cleanliness.