Simultaneous Determination of the Costunolide and Dehydrocostus Lactone in Haoweilai Soft Capsule by HPLC
	    		
		   		
		   			
		   		
	    	
    	 
    	10.6039/j.issn.1001-0408.2016.15.28
   		
        
        	
        		- VernacularTitle:HPLC法同时测定好胃来软胶囊中木香烃内酯和去氢木香内酯的含量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Mingming ZHAO
			        		
			        		;
		        		
		        		
		        		
			        		Yuting CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Bangrui HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiangqun JIN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Haoweilai soft capsule;
			        		
			        		
			        		
				        		HPLC;
			        		
			        		
			        		
				        		Costunolide;
			        		
			        		
			        		
				        		Dehydrocostus lactone
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacy
	            		
	            		 2016;27(15):2099-2101
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	OBJECTIVE:To establish a method for the simultaneous determination of costunolide and dehydrocostus lactone in Haoweilai soft capsule. METHODS:HPLC was performed on the column of Dikma C18 with mobile phase of acetonitrile- water (V/V,55∶45) at a flow rate of 1.0 ml/min,detection wavelength was 225 nm,column temperature was 25 ℃,and the injection volume was 10 μl. RESULTS:The linear range were 24.00-108.00 μg/ml(r=0.999 7) for costunolide and 20.88-93.98 μg/ml for dehydrocostus lactone (r=0.999 8);RSDs of precision,stability and reproducibility tests were lower than 1%;recoveries were 98.71%-100.00%(RSD=0.25%,n=6)and 96.88%-99.18%(RSD=0.40%,n=6). CONCLUSIONS:The method is simple with good stability and reproducibility,and can be used for the simultaneous determination of costunolide and dehydrocostus lactone in Haoweilai soft capsule.