Visual quality observation after implantation of TICL for high myopia with astigmatism
	    		
		   		
		   			
		   		
	    	
    	 
    	10.11659/jjssx.1672-5042.201403004
   		
        
        	
        		- VernacularTitle:TICL植入治疗合并散光的高度近视视觉质量疗效观察
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Yan WU
			        		
			        		;
		        		
		        		
		        		
			        		Tao LUO
			        		
			        		;
		        		
		        		
		        		
			        		Wei JIANG
			        		
			        		;
		        		
		        		
		        		
			        		Hengdi ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Yajing ZHAO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		toric implantable contact lens;
			        		
			        		
			        		
				        		high myopia;
			        		
			        		
			        		
				        		myopic astigmatism;
			        		
			        		
			        		
				        		contrast sensitivity;
			        		
			        		
			        		
				        		visual quality
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Regional Anatomy and Operative Surgery
	            		
	            		 2014;(3):234-237
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To assess the clinical outcomes about the visual qulitity of toric implantable contact lens ( TICL) implantation for high myopia with astigmatism. Methods Fifty-two eyes of 27 patients that underwent TICL implantation were examined. Uncorrected visual acuity( UCVA) ,best corrected visual acuity( BCVA) ,refraction,contrast sensitivity ( CS) with and without glare were evaluated before and after the treatment. Results Significant improvement in UCVA and BCVA were found at 1 month and 6 months after treatment (P<0. 05). The refraction at 1 month ( -0. 56 ± 0. 42)D and 6 months ( -0. 58 ± 0. 22)D after treatment were of no significant difference (P>0. 05), and the astigmatism at 1 month ( -0. 35 ± 0. 60)D and 6 months ( -0. 31 ± 0. 42)D after treatment were of no significant difference either (P>0. 05). The CS with and without glare were all significantly better than results before operation for 6. 0,12. 0 and 18. 0 cycles/degree (P<0. 05),but there were no significant difference between 1 month and 6 months after treatment (P>0. 05). No significant difference were found preoperatively,1 month after treatment and 6 months after treatment in terms of CS with and without glare (P>0. 05). The satisfaction of this investigation was 100%. Conclusion The TICL performed well in correcting high myopia with astigmatism,and it is a good surgical option for the treatment.