The feasibility study of radiation absorbed dose measurement using oligonucleotide dually labeled with Alexa Fluor 488 and BHQ1 probe
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.0254-5098.2016.06.004
   		
        
        	
        		- VernacularTitle:应用Alexa Fluor 488与BHQ1双标记寡核苷酸荧光探针测量辐射吸收剂量的可行性研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Wenwen LIN
			        		
			        		;
		        		
		        		
		        		
			        		Panying SHI
			        		
			        		;
		        		
		        		
		        		
			        		Baoguo ZHANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Fluorescent probe;
			        		
			        		
			        		
				        		Alexa Fluor 488;
			        		
			        		
			        		
				        		BHQ1
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Radiological Medicine and Protection
	            		
	            		 2016;36(6):419-423
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To study the feasibility of measuring radiation absorbed dose with the fluorescent probe Alexa Fluor 488-DNA-BHQ1.Methods An oligonucleotide dually labeled at its 5'-and 3'-end with fluorescent molecular Alexa Fluor 488 and specific fluorescence inhibitors BHQ1 was prepared.The Alexa Fluor 488-DNA-BHQ1 aqueous solution was exposed with X-ray and its fluorescence intensity was measured.Results When the concentration of Alexa Fluor 488-DNA-BHQ1 was between 0.5 and 1 μmol/L,the fluorescence intensity of its aqueous solution had excellent linear dose response from 0.1 to 30 Gy (R2 =0.99) and it was stably maintained after 40-80 min of irradiation especially at 4℃.Conclusions In the dose range of 0.1-30 Gy,the Alexa Fluor 488-DNA-BHQ1 fluorescent probe can be used to measure radiation absorbed dose.