Determination of Morphine Sulfate Sustained Release Suppositories by HPLC
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:高效液相色谱法测定硫酸吗啡缓释栓含量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Dan LI
			        		
			        		;
		        		
		        		
		        		
			        		Benhong ZHOU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Morphine sulfate;
			        		
			        		
			        		
				        		Sustained release suppositories;
			        		
			        		
			        		
				        		HPLC
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			China Pharmacist
	            		
	            		 2016;19(2):372-374
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To prepare morphine sulfate sustained-release suppositories and determine the content by HPLC. Methods:An Eclipse XDB-C18 (150 mm × 4. 6 mm,5 μm) chromatographic column was used, methanol-heptane sulfonic acid sodium acetate solu-tion(2. 02 g sodium heptanesulfonate was dissolved in appropriate amount of water and 5ml glacial acetic acid was added, and then water was added to 1000 ml, shaken up) (50 ∶50) was used as the mobile phase, the flow rate was 1. 0 ml·min-1 , the detection wavelength was 233 nm, the column temperature was 25℃ and the sample size was 10μl. Results:The average content of morphine in 3 batches of samples was 99. 9%, the linear range of 4. 18-86. 60μg·ml-1 was good (r=0. 999 3), and the average recovery was 100. 6% (RSD=1. 58%, n=9). Conclusion:The method is sensitive, rapid and accurate, and suitable for the quality control of morphine sulfate sus-tained-release suppositories.