Root cause analysis in continuous improvement of cleaning quality of reusable medical instruments
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1671-9638.2015.12.004
   		
        
        	
        		- VernacularTitle:利用根因分析法持续改进复用医疗器械清洗质量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Shihua LIU
			        		
			        		;
		        		
		        		
		        		
			        		Yingchun HE
			        		
			        		;
		        		
		        		
		        		
			        		Zhongyuan YIN
			        		
			        		;
		        		
		        		
		        		
			        		Liping GUO
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		reusable medical instrument;
			        		
			        		
			        		
				        		root cause analysis;
			        		
			        		
			        		
				        		cleaning quality;
			        		
			        		
			        		
				        		continuous quality improvement;
			        		
			        		
			        		
				        		infection control
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Infection Control
	            		
	            		 2015;(12):807-810
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To improve the cleaning quality of reusable medical instruments continuously through root cause analysis,reduce healthcare-associated infection(HAI)and the wear and tear of instruments.Methods The major factors influencing the cleaning quality of instruments were analyzed and clarified by fishbone diagram,contin-uous quality improvement was carried out based on 5 terminal factors,the rate of rusting,stain,repeated cleaning, damage,and clinical department satisfaction before and after the implementation of continuous improvement were compared.Results The qualified rate of instrument clean increased from 94.24% before implementing measures to 97.60% after implementing measures,the rate of rusting,stain,repeated cleaning,damage decreased from 3.39%, 2.37%,5.76%,and 2.08% to 1 .55%,0.85%,2.40%,and 0.48% respectively,there were significant difference among different groups(all P <0.001 );the score of satisfaction rate to central sterile supply department elevated from(93.87±3.87)before implementing measures to (98.08 ±0.59)after implementing measures(t =6.80,P <0.001).Conclusion Root cause analysis is important in improving cleaning quality of reusable instruments continu-ously,as well as reducing HAI and the wear and tear of instrument,it can save medical cost.