Comparison of two position implant-supported molar distalization systems
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1001-3733.2014.06.026
   		
        
        	
        		- VernacularTitle:比较2种部位种植钉支抗推上颌磨牙向远中移动的效果
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Shuxia CUI
			        		
			        		;
		        		
		        		
		        		
			        		Ruiqi DING
			        		
			        		;
		        		
		        		
		        		
			        		Shumin WANG
			        		
			        		;
		        		
		        		
		        		
			        		Wei YUAN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Micro-implant;
			        		
			        		
			        		
				        		Molar distalization;
			        		
			        		
			        		
				        		Infrazygomatic crest
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Practical Stomatology
	            		
	            		 2014;(6):849-852
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To compare 2 position implant-supported molar distalization systems in clinical application.Methods:25 pa-tients with Class II and mild to moderate crowding dentition were included,18 females and 7 males,aged 15 to 29 years old(22.58 on average ).All the patients were treated with non-extraction method by distalizing the upper molar with micro-implant anchorage.In ex-perimental group(n =12)the micro-implants were inserted on infrazygomatic crest above the maxillary first molar mesial buccal root. In control group(n =13)the micro-implants were inserted on buccal alveolar bone between maxillary second premolar and maxillary first molar.In both groups micro-implants were inserted to distalize the maxillary molars.The displacement patterns of maxillary inci-sors and molars were measured and compared.Results:Successful primary micro-implant placement was obtained in 87.5%(21 /24) of the implantation in control group and 100%(26 /26)in experimental group.The distal movement(mm)of the molars in control and experiment group was 2.29 ±0.96 and 2.91 ±0.96 respectively(P >0.05).Experimental group showed significant intrusive displace-ment of the molars.Horizontal incisor displacement in experimental group was more than that in control group.Conclusion:Micro-im-plant inserted in infrazygomatic crest may facilitate intrusion and distalization of the maxillary molar and incisor.