Application of high-fluorescence body fluid cell mode on the platform Sysmex XE-5000 automated blood analyzer in diagnosis of meningeal carcinomatosis
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1673-4130.2015.13.017
   		
        
        	
        		- VernacularTitle:Sysmex XE-5000全自动血液分析仪高荧光体液细胞计数在脑膜癌诊断中的应用
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jiamei CHEN
			        		
			        		;
		        		
		        		
		        		
			        		Huiming YE
			        		
			        		;
		        		
		        		
		        		
			        		Xiaofen XIAO
			        		
			        		;
		        		
		        		
		        		
			        		Yang YU
			        		
			        		;
		        		
		        		
		        		
			        		Xianming LIANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		meningeal carcinomatosis;
			        		
			        		
			        		
				        		cerebrospinal fluid cytology;
			        		
			        		
			        		
				        		high-fluorescence body fluid cell
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			International Journal of Laboratory Medicine
	            		
	            		 2015;(13):1841-1843
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To evaluate the performance of high-fluorescence body fluid cell (HF-BF)mode on the platform Sysmex XE-5000 automated blood analyzer,and analyse its clinical application value in diagnosis of meningeal carcinomatosis.Methods E-valuated the performance of HF-BF by using precision test and methodology comparison test.Retrospectively analyzed 295 test re-sults of cerebrospinal fluid in Zhongshan Hospital Affiliated to Xiamen University from June 2010 to September 2012.Results HF-BF on the platform Sysmex XE-5000 automated blood analyzer had high precision,and exhibited a good consistency with cytolgical examination.The percentage of high-fluorescence body fluid cell(HF-BF%)in the meningeal carcinomatosis group was higher than that in other cerebral diseases groups,had statistically significant differences (P < 0.05 ).The cut-off value for HF-BF% was 4.3%,while the area under a receiver operating characteristic (ROC)curve (AUC)was 0.933,the sensitivity was 95.2%,and the specificity was 92.7%.When HF-BF% was over 4.3%,it was more likely to detect tumor cell in cerebrospinal fluid cytology.Con-clusion HF-BF is an effective reference index for the early diagnosis of meningeal carcinomatosis and has significant clinical appli-cation value.