Sensitive determination of 4-O-methylhonokiol in rabbit plasma by high performance liquid chromatography and application to its pharmacokinetic investigation
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Mingyue LI
			        		
			        		;
		        		
		        		
		        		
			        		Yuhai TANG
			        		
			        		;
		        		
		        		
		        		
			        		Xia LIU
			        		
			        		;
		        		
		        		
		        		
			        		Haiyan Lü
			        		
			        		;
		        		
		        		
		        		
			        		Xiyan SHI
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		4-O-methylhonoliol;
			        		
			        		
			        		
				        		Cortex Magnoliae Officinalis;
			        		
			        		
			        		
				        		high performance liquid chromatography;
			        		
			        		
			        		
				        		pharmacokinetic
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Pharmaceutical Analysis
	            		
	            		 2011;01(2):108-112
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	A novel high performance liquid chromatographic method was developed for the determination of 4-O-methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation.Plasma samples were treated by one-fold volume of methanol and acetonitrile to remove the interference proteins.A reverse phase column of SHIMPACK VP-ODS (150 mm× 4.6 mm,5.0 μm) was used to separate 4-O-methylhonokiol in the plasma samples.The detection limit of 4-O-methylhonokiol was 0.2 μg/L and the linear range was 0.012- 1.536 mg/L.The good extraction recoveries were obtained for the spiked samples (84.7%,89.3% and 87.7% for low,middle and high concentrations of added standards,respectively).The relative standard deviation of intra-day and inter-day precisions was in the range from 0.6% to 13.5%.The pharmacokinetic study of 4-O-methylhonokiol was made and the results from the plasmaconcentration curve of 4-O-methylhonokiol showed a two-apartment open model.This work developed a sensitive,stable and rapid HPLC method for the determination of 4-O-methylhonokiol and the developed method has been successfully applied to a pharmacokinetic study of 4-O-methylhonokiol.