Determination of S-isomer in Epinephrine Hydrochloride Injection by HPLC with Chiral Mobile Phase Additives
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3870/yydb.2015.06.026
   		
        
        	
        		- VernacularTitle:高效液相色谱手性流动相法测定盐酸肾上腺素注射液中 S-对映体含量
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Li JIN
			        		
			        		;
		        		
		        		
		        		
			        		Jianli ZHOU
			        		
			        		;
		        		
		        		
		        		
			        		Xiaodan ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Zhuoliang GU
			        		
			        		;
		        		
		        		
		        		
			        		Ying BU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Epinephrine injection,hydrochloride;
			        		
			        		
			        		
				        		Chromatography,high performance liquid;
			        		
			        		
			        		
				        		Chiral mobile phase;
			        		
			        		
			        		
				        		Additives;
			        		
			        		
			        		
				        		S-isomer
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Herald of Medicine
	            		
	            		 2015;(6):799-801
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To establish a method for the chiral separation and determination of S-isomer in epinephrine hydrochloride injection by HPLC with chiral mobile phase additives. Methods Column of Purospher? STAR RP-18 (4. 6 mm×250 mm, 5 μm) was used. The mobile phase was acetonitrile-10 mmol·L-1 sodium dihydrogen phosphate buffer containing 10 mmol·L-1 sulfobutylether-b-cyclodextrin (pH adjusted to 3. 0 with phosphoric acid) (98. 5:1. 5), detection wavelength was 280 nm, the flow rate was 0. 8 mL·min-1 , and the column temperature was 30 ℃ . Results Good linear relationship was established between the peak area and the concentration of S-isomer over the range of 5. 02-1501. 50 μg·mL-1 (R2 =0. 999 7). The detection limit was 0. 05 μg·mL-1 . Conclusion The proposed method shows high repeatability and durability. It can be employed for the quality control of S-isomer in epinephrine hydrochloride injection.