Biomechanical analysis on the fixation of mandibular condyle with sagittal fracture by double plates in 3 ways
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1001-3733.2015.04.015
   		
        
        	
        		- VernacularTitle:3种不同方式的双板法坚固内固定髁突矢状骨折生物力学分析
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Jie JING
			        		
			        		;
		        		
		        		
		        		
			        		Yuna HEI
			        		
			        		;
		        		
		        		
		        		
			        		Ling TIE
			        		
			        		;
		        		
		        		
		        		
			        		Jia LI
			        		
			        		;
		        		
		        		
		        		
			        		Jinhua TIAN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Sagittal fracture ofthe mandibular condyle(SFMC);
			        		
			        		
			        		
				        		Rigid fixation;
			        		
			        		
			        		
				        		Finite element analysis(FEA);
			        		
			        		
			        		
				        		Biomechanics;
			        		
			        		
			        		
				        		Stress
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Practical Stomatology
	            		
	            		 2015;(4):520-525
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To analyze the biomechanical stress distribution on the sagittal fractured of the mandibular condyle(SFMC) fixed by double plates in 3 different ways.Methods:The fixation finite element models with double straight plates(SS),one straight and one L-form plates(SL),and double L-form plates(LL)were established.The biomechanical stresses on condyle were calculated with finite element analysis.Results:In the model of SS fixation the maximum equivalent stress (MES),maximum total displacement (MTD)and maximum total corner(MTC)of condylar stump were 525.475 MPa,0.902 2 mm and 0.260 1°;MES,MTD,and MTC on fractured free-end were 4.425 MPa,0.882 7 mm and 0.019 9°,respectively.In the model of SL fixation MES,MTD and MTC on condylar stump were 1 135 MPa,0.9367 mm and 0.126 1°;MES,MTD and MTC on fractured free-end were 2.656 MPa,0.887 1 mm and 0.016 9°,respectively.In the model of LL fixation MES,MTD and MTC on condylar stump were 2 208 MPa,0.923 8 mm and 0.172 2°;MES,MTD and MTC on fractured free-end were 14.66 8 MPa,0.876 6 mm and 0.018 1°,respectively.Conclusion:Double L plates fixation is a proper way for SFMC.