Effects on glucose control of abnormal glucose metabolism during pregnancy by continuous glucose monitoring system
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1671-7368.2014.07.016
   		
        
        	
        		- VernacularTitle:连续血糖监测对于妊娠期糖代谢异常血糖控制作用的研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Chenchen ZHOU
			        		
			        		;
		        		
		        		
		        		
			        		Zujing YANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Glucose metabolism,gestational;
			        		
			        		
			        		
				        		Blood glucose;
			        		
			        		
			        		
				        		Monitoring
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of General Practitioners
	            		
	            		 2014;13(7):577-579
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	For the case study group,52 pregnant women diagnosed as abnormal glucose metabolism and requiring in-hospital glucose control were selected for continuous glucose monitoring.And another 49 pregnant women with known glucose levels through serial glucose monitoring at the same period were taken as case control group.We divided the case study group into A1,A2 and B based on White's typing.In case study group,the glucose levels peaked at 8 to 10 am and dropped to the lowest levels at 10 pm to 6 am on the next day.The glucose of A2 group was markedly higher than that of A1 group.The highest postprandial glucose of case study group happens at (1.6 ± 0.5) h after breakfast,(1.6 ± 1.2) h after lunch and (1.6 ± 0.8) h after dinner.The blood glucose wavy coefficient of patients of A1 and A2 groups had significant statistical difference.The newborn weight of case study group was lower than that of case control group.