The effects of commonly used dental cast metal posts and cores on MRI
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1001-3733.2014.04.03
   		
        
        	
        		- VernacularTitle:口腔常用铸造金属桩核对磁共振成像的影响
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qingyun MA
			        		
			        		;
		        		
		        		
		        		
			        		Xin LI
			        		
			        		;
		        		
		        		
		        		
			        		Ye SONG
			        		
			        		;
		        		
		        		
		        		
			        		Lu WANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Magnetic resonance imaging(MRI);
			        		
			        		
			        		
				        		Metal post and core;
			        		
			        		
			        		
				        		Artifacts
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Practical Stomatology
	            		
	            		 2014;(4):460-463
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective:To observe the influence of commonly used dental cast metal posts and cores on magnetic resonance imaging (MRI)for head and neck.Methods:Six kinds of posts and cores made of metal alloy (Ni-Cr alloy,Co-Cr alloy,titanium alloy,pure titanium,Pd-Au alloy and Au-Pt alloy)were respectively fixed on the mucosa of left palate of a volunteer.The maxillofacial region of the subjects was scanned by routine head sequences SE-T1WI and TSE-T2WI respectively.Results:ANOVA of factorial design analy-sis indicated significant differences of artifacts among metal materials(F=153.63,P<0.05),scanning sequences(F=70.94,P<0.05)and the number of cast posts and cores(F=102.73,P<0.05).In both sequences the size of metal artifacts were as following:Pd -Au alloy>Co-Cr alloy>Ni-Cr alloy>Au-Pt alloy>titanium alloy>pure titanium;two posts and cores>one post and core;SE-T1WI>TSE-T2WI.Conclusion:Different cast metal posts and cores have different influences on MRI artifact.Reasonably choosing the metal materials and scanning sequences can minimize artifacts on MRI.