Consistency study in the measurement of epicardial adipose tissue volume using non-ECG-gated CT and ECG-gated CT
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3969/j.issn.1002-1671.2014.06.012
   		
        
        	
        		- VernacularTitle:非心电门控 CT 与心电门控 CT测量心外膜下脂肪体积的一致性研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qingshan WU
			        		
			        		;
		        		
		        		
		        		
			        		Yanman ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Wen JIANG
			        		
			        		;
		        		
		        		
		        		
			        		Lemin TANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		computed tomography;
			        		
			        		
			        		
				        		epicardial adipose tissue;
			        		
			        		
			        		
				        		coronary atherosclerotic
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Journal of Practical Radiology
	            		
	            		 2014;(6):937-942
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To investigate the consistency in the measurement of epicardial adipose tissue (EAT)volume using non-ECG-gated CT and ECG-gated CT.Methods ECG-gated CT and non-ECG-gated CT examinations were obtained in 104 subjects. The ECG-gated group was outlined the epicardium by an associate chief physician with a hand-painted method,the CT value of quan-titative adipose tissue was ranged from -30 HU to -250 HU.The non-ECG-gated group was outlined the epicardium by two asso-ciate chief physicians,A and B;The two CT values were ranged from -20 HU to -250 HU and from -30 HU to -250 HU,re-spectively.The measurement results of two groups were compared for the analysis of the relationship between EAT volume and cor-onary atherosclerosis.Results After the employment of CT value ranging from -20 HU to -250 HU for non-ECG-gated group, the measurement result was well consistent with ECG-gated group.The measurement results obtained by two associate chief physi-cians using the same range of CT value were in a good consistency.The EAT volumes obtained by various measurements were all correlated to the occurrence of coronary atherosclerosis.Conclusion After adjusting the range of CT value,two methods were in a good consistency.Non-ECG-gated CT measurement of EAT volume is easy to operate,which has a better practical value.