Effects of pulmonary static inflation with different pressures on postoperative lung function in patients undergoing cardiac valve replacement with cardiopulmonary bypass
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.0254-1416.2013.11.001
   		
        
        	
        		- VernacularTitle:不同压力静态膨肺对患者体外循环心脏瓣膜置换术后肺功能的影响
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Shuangbo DAI
			        		
			        		;
		        		
		        		
		        		
			        		Miaoning GU
			        		
			        		;
		        		
		        		
		        		
			        		Juan QI
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Pressure;
			        		
			        		
			        		
				        		Extracorporeal circulation;
			        		
			        		
			        		
				        		Respiratory function tests;
			        		
			        		
			        		
				        		Pulmonary static inflation
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Anesthesiology
	            		
	            		 2013;33(11):1293-1295
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To evaluate the effects of pulmonary static inflation with different pressures on postoperative lung function in patients undergoing cardiac valve replacement with cardiopulmonary bypass (CPB).Methods Sixty ASA Ⅱ or Ⅲ patients,aged 26-70 yr,weighing 47-78 kg,undergoing elective cardiac valve replacement with CPB,were randomly divided into 2 groups (n =30 each):pulmonary static inflation with 5 cm H2O group (group L) and with 10 cm H2O group (group H).In L and H groups,pulmonary static inflation was performed with the pressure maintained at 5 and 10 cm H2O,respectively,after stopping mechanical ventilation during CPB.Arterial blood samples were taken before skin incision and at 1,3 and 6 h after termination of CPB for blood gas analysis.The alveolar-arterial oxygen pressure difference (D(A-a)O2),respiratory index (RI) and oxy.genation index (OI) were calculated.The indwelling time of endotracheal tube after operation and duration of ICU stay were recorded.Results Compared with group L,D(A-a)O2 and RI were significantly decreased and OI was increased at 1,3 and 6 h after termination of CPB,the incidence of OI less than 300 mm Hg was decreased (P < 0.05),and no significant change was found in the indwelling time of endotracheal tube after operation and duration of ICU stay in H group (P > 0.05).Collusion Pulmonary static inflation with 10 cm H2O can better improve postoperative pulmonary diffusion function than with 5 cm H2O in patients undergoing cardiac valve replacement with CPB.