Assessment of myocardial perfusion by the microbubble replenishment parameters of real-time myocardial contrast echocardiography
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004-4477.2011.12.003
   		
        
        	
        		- VernacularTitle:实时心肌超声造影微泡再充盈参数评价心肌梗死患者心肌灌注
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Peng LI
			        		
			        		;
		        		
		        		
		        		
			        		Bowen ZHAO
			        		
			        		;
		        		
		        		
		        		
			        		Youbin DENG
			        		
			        		;
		        		
		        		
		        		
			        		Haoyi YANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaojun BI
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Echocardiography;
			        		
			        		
			        		
				        		Myocardial infarction;
			        		
			        		
			        		
				        		Myocardial reperfusion
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2011;20(12):1021-1024
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	ObjectiveTo assess myocardial perfusion by the end-systolic and end-diastolic replenishment parameters of real-time myocardial contrast echocardiography (MCE).MethodsTwenty-one patients with myocardial infarction(MI) and normal control group of 6 cases underwent intravenous realtime myocardial contrast echocardiography via slow and homogeneous venous injections of SonoVue.MCE images were obtained from the apical 4-chamber,2-chamber,and long-axis views.According to the exponential function:y(t) =A [1 - e-kt] + B,the time intensity curves were obtained.By an off-line ECG triggering and curve fitting,the replenishment parameters A value,k value,A × k value were obtained separately from end-systolic and end-diastolic images.ResultsIn normal control group,the end-systolic replenishment parameters A value,k value,A × k value were all lower than that of the end-diastolic replenishment parameters[(6.21 ± 2.69)dB vs (7.93 ± 3.66)dB,P <0.05;0.36 ± 0.15 vs 0.42 ± 0.19,P < 0.01 ;2.88 ± 1.29 vs 3.39 ± 1.61,P <0.05,respectively].The end-diastolic replenishment parameters were found significantly greater variability than the end-systolic values (variation coefficient CV:A value 46.2% vs 43.3%,k value 45.2% vs 41.4%,A× k value 47.5% vs 44.8%,all P <0.05).In 21 patients,the end-systolic replenishment parameters in myocardial segments supplied by infarct-related coronary artery were significantly lower than that in myocardial segments supplied by non - infarct - related coronary artery.ConclusionsThe end-systolic and end-diastolic replenishment parameters of real time myocardial contrast echocardiography can assess myocardial perfusion.The variability of the end-systolic replenishment parameters is smaller than that of the end diastolic parameters.Significant variability in k-value suggests that this parameter is best suited for before-after study in the same patient.