Measurement of virtual touch tissue quantification in healthy liver of adults
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004-4477.2011.12.011
   		
        
        	
        		- VernacularTitle:成年人正常肝声触诊组织定量正常值的研究
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Qiaoying ZHU
			        		
			        		;
		        		
		        		
		        		
			        		Xingtian WANG
			        		
			        		;
		        		
		        		
		        		
			        		Jianhua CUI
			        		
			        		;
		        		
		        		
		        		
			        		Pengxi WU
			        		
			        		;
		        		
		        		
		        		
			        		Peipu SHEN
			        		
			        		;
		        		
		        		
		        		
			        		Rong WANG
			        		
			        		;
		        		
		        		
		        		
			        		Wei WANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Ultrasonography;
			        		
			        		
			        		
				        		Liver;
			        		
			        		
			        		
				        		Virtual touch tissue quantification
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2011;20(12):1043-1046
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	ObjectiveTo explore the feasibility of detecting liver stiffness by virtual touch tissue quantification (VTQ) technique and establish a reference range of shear-wave velocity in healthy liver of adults.MethodsOne hundred and sixty-one healthy adults underwent VTQ detection to obtain the shearwave velocities of livers.Each subject received VTQ measurement in four parts of liver.Ten subjects were performed twice by two sonographers,respectively.Results① The liver shear-wave velocities of 161 healthy adults had a 95% confidence interval from 1.089 to 1.105 m/s.Shear-wave speed values of intrahepatic different parts had no statistically significant.The ICC of measurement value of four parts in healthy liver was 0.80(95 % CI:0.75- 0.85).②The difference of shear-wave velocities in healthy livers in different age groups had no statistically significant,whereas the mean values in different gender had statistically significant (P =0.001).③No statistically significant was observed between the mean shear-wave velocity values obtained by different operators (P =0.82).ConclusionsThe liver shear-wave velocities of the healthy group have a reference range from 1.089 to 1.105 m/s.VTQ technique has a good reproduction and stability,therefore,using this technology to assess hepatic stiffness is noninvasive and feasible.