"Leukocyte differential count in peripheral blood ""with"" single tube/ten colors""flow cytometry"
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1009-9158.2011.05.003
   		
        
        	
        		- VernacularTitle:单管10色流式细胞术分类计数外周血白细胞
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xuekai LIU
			        		
			        		;
		        		
		        		
		        		
			        		Jianzhong WANG
			        		
			        		;
		        		
		        		
		        		
			        		Ying XING
			        		
			        		;
		        		
		        		
		        		
			        		Chenxue QU
			        		
			        		;
		        		
		        		
		        		
			        		Chengwei PU
			        		
			        		;
		        		
		        		
		        		
			        		Ping WU
			        		
			        		;
		        		
		        		
		        		
			        		Hui WANG
			        		
			        		;
		        		
		        		
		        		
			        		Kangyuan LIU
			        		
			        		;
		        		
		        		
		        		
			        		Lan MA
			        		
			        		;
		        		
		        		
		        		
			        		Na PAN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Leukocyte differential count;
			        		
			        		
			        		
				        		Flow cytometry;
			        		
			        		
			        		
				        		Blood cell count
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Laboratory Medicine
	            		
	            		 2011;34(5):395-402
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To explore the values of potential clinical application ofsingle tube/ten colorsflow cytometry for leukocyte differential count in peripheral blood.Methods Utilizing multiple monoclonal antibody combinations and the vavious logical gating strategies,the single tube/12 antibodies with no-wash method for the leukocyte differential count in peripheral blood were determined by using 10 colors flow cytometry.Leukocyte differentials of 142 peripheral blood samples were determined by both Beckman-Coulter LH750 hematology analyzer and 10 colors flow cytometry.The results were then compared to standard microscopic examination as a reference method.The clinical diagnostic efficiency ofsingle tube/10 colorsflow cytometry was calculated.The correlations between standard microscopic cytology,single tube/10 colorsflow cytometry and the hematology analyzer were determined.In addition,the clinical diagnosis efficiency for blast counts ofsingle tube/10 colorswere compared to the results determined by BD FACS Calibur flow cytometer.Results The leukocyte differentials were correlated well between the single tube/10 colorsflow cytometry and standard microscopic cytology(r>0.700,P<0.01) except for basophils.The correlations with neutrophilic granulocytes,lymphocytes,immature granulocytes and blasts were superior(r=0.972,0.951,0.801,0.912,respectively,P<0.01).When 1% was selected as the cut-off point for immature granulocytes determined by standard microscopic cytology,the sensitivity and the specificity ofsingle tube/10 colorsflow cytometry were 92%(57/62) and 79% (63/80),respectively.When 0.5% was selected as the cut-off point for blasts detected by standard microscopic cytology,the sensitivity and the specificity were 99% (67/68) and 92% (68/74).Using the immunophenotyping results from BD FACS Calibur as a standard,the sensitivity for detecting blasts bysingle tube/10 colOrsflow cytometry was 100% (40/40),the specificity was 91% (10/11),the positive predictive value was 98% (40/41),the negative predictive value was 100% (10/10) and the accuracy was 98% (50/51).Conclusions Thesingle tube/10 colorsflow cytometry has a excellent correlation with the standard microscopic cytology when applied on leukocyte differential count in peripheral blood.It may potentially use as a subsequent method for verification of abnormal results of complete blood cell count in the future.