Comparison of the imaging effects of SonoVue and Sonazoid at high frequency in rabbit-liver ultrasonography
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1004-4477.2011.04.026
   		
        
        	
        		- VernacularTitle:SonoVue与Sonazoid高频条件下对兔肝显像效果的对比分析
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Hui GUO
			        		
			        		;
		        		
		        		
		        		
			        		Longzhong LIU
			        		
			        		;
		        		
		        		
		        		
			        		Wei ZHENG
			        		
			        		;
		        		
		        		
		        		
			        		Anhua LI
			        		
			        		;
		        		
		        		
		        		
			        		Yuhong LI
			        		
			        		;
		        		
		        		
		        		
			        		Jianwei WANG
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Ultrasonography;
			        		
			        		
			        		
				        		Microbubbles;
			        		
			        		
			        		
				        		Liver
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Ultrasonography
	            		
	            		 2011;20(4):344-347
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To compare the contrast enhancement effects of SonoVue and Sonazoid in rabbit liver at ultrasonic frequency of 7 MHz using various mechanical index(MI) and dosage. Methods Eight rabbits were bolus injected with different contrast agents:for SonoVue(0. 06 ml/kg,0. 12 ml/kg) ,MI ranging 0. 10 - 0. 55; while Sonazoid (0. 045 ml/kg, 0. 09 ml/kg) , MI ranging 0. 19 - 0. 98. Quantitative analysis of ultrasonography was done using video-intensity analysis system, and peak intensity (PI) was compared. Results With the same frequency, in SonoVue group, for both dosage groups, PI reached maximum at MI = 0. 15 ( P <0. 05) ; with the same MI, PI of the high dosage group was higher ( P < 0. 05). In Sonazoid group,for both dosage groups,PI reached maximum at MI = 0. 40( P <0. 05) ; with the same MI,PI of the high dose group was higher ( P <0. 05). Conclusions The optimistic ultrasonographic conditions provided to SonoVue and Sonazoid are different. Dosage of contrast agents, MI and frequency need to be concerned.