Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report.
	    		
		   		
		   			
		   		
	    	
    	 
    	10.4097/kjae.2014.67.5.346
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Daisuke SUGIYAMA
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Shigeo IKENO
			        		
			        		;
		        		
		        		
		        		
			        		Tetsuya TSUCHIHASHI
			        		
			        		;
		        		
		        		
		        		
			        		Shigeru YOKOTA
			        		
			        		;
		        		
		        		
		        		
			        		Hiroaki INA
			        		
			        		;
		        		
		        		
		        		
			        		Tetsuya KONO
			        		
			        		;
		        		
		        		
		        		
			        		Kunihiko YAMASHITA
			        		
			        		;
		        		
		        		
		        		
			        		Mikito KAWAMATA
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Anesthesia, Japanese Red Cross Society of Suwa Hospital, Suwa, Japan. sugidai@shinshu-u.ac.jp
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Case Report
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		False aneurysm;
			        		
			        		
			        		
				        		Pulmonary artery;
			        		
			        		
			        		
				        		Swan-Ganz catheterization
			        		
			        		
	        			
        			
        		
 
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Aneurysm, False*;
				        		
			        		
				        		
					        		Aortic Aneurysm, Thoracic*;
				        		
			        		
				        		
					        		Catheterization;
				        		
			        		
				        		
					        		Catheterization, Swan-Ganz*;
				        		
			        		
				        		
					        		Catheters;
				        		
			        		
				        		
					        		Diagnosis;
				        		
			        		
				        		
					        		Hemorrhage*;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Lung;
				        		
			        		
				        		
					        		Pulmonary Artery*;
				        		
			        		
				        		
					        		Rupture
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:Korean Journal of Anesthesiology
	            		
	            		 2014;67(5):346-349
	            	
            	
 
            
            
            	- CountryRepublic of Korea
 
            
            
            	- Language:English
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due to a traumatic PA false aneurysm. The Swan-Ganz catheter might have been displaced by the thoracic aortic aneurysm with displacement of the catheter causing the false aneurysm and bleeding.