An Improvement of Chemiluminescent System for Determination of Peroxynitrite Anion
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:过氧亚硝基-鲁米诺化学发光体系的改进
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xianbing FAN
			        		
			        		;
		        		
		        		
		        		
			        		Xiaofeng LIANG
			        		
			        		;
		        		
		        		
		        		
			        		Danian SHA
			        		
			        		;
		        		
		        		
		        		
			        		Chao HAN
			        		
			        		;
		        		
		        		
		        		
			        		Tianxi HU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		chemiluminescence;
			        		
			        		
			        		
				        		peroxynitrite anion;
			        		
			        		
			        		
				        		antioxidants
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Progress in Biochemistry and Biophysics
	            		
	            		 2001;28(2):251-255
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	An improvement of chemiluminescent system for determination of peroxynitrite anion (ONOO-) has been made. In this system, the effect of some antioxidants for scavenging ONOO- was tested. The constitute of this system and the program of starting were followed as: The ozone (O3) was bubbled through a glass-frit into 10 ml 0.01 mol/L solution of sodium azide in CB(pH 10.5) to generate ONOO-. The 800 μl ozonized solution of azide was injected into a glass tude in situ which contains 100 μl sample and 100 μl luminol solutions to initiate chemiluminescence (CL). The pluses / 6 seconds (CP6S) were determined immediately and continually for 10~30 times. A certain CL intensity (CP6S) was chosen as evaluation index to compare the activity of antioxidants. This chemiluminescent system is sensible, simple and stable. The determination limit was 8.74 μmol/L ONOO-. The linear rang was 8.74~74.04 μmol/L ONOO-. The intra batch and inter batch variation coefficient (CV%) of the analysis were 3.35%(n=10) and 5.52%(n=10) respectively. It was tested that Vit.C, teapolyphenol, procyanidin and thiourea all have effects on scavenging ONOO-.