Biomechanical evaluation of connectible skills using iliac screw and lumbar-sacral spine pedicle screw in the fixation between lumbar-sacral spine and pelvis
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:髂骨钉与腰骶椎弓根钉连接技术在腰骶骨盆固定中的生物力学评价
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Rukun SU
			        		
			        		;
		        		
		        		
		        		
			        		Xingmo LIU
			        		
			        		;
		        		
		        		
		        		
			        		Yinghui DENG
			        		
			        		;
		        		
		        		
		        		
			        		Fobao LI
			        		
			        		;
		        		
		        		
		        		
			        		Tao PAN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Tissue Engineering Research
	            		
	            		 2008;12(22):4377-4379
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	BACKGROUND: There have been many methods of fixation between lumbar-sacral spine and pelvis. However, a safe, firm, and ideal method of internal fixation has not been found.OBJECTIVE: This study was designed to investigate the stability of the fixation between lumbar-sacral spine and pelvis with the connectible skills using iliac screw and lumbar-sacral spine pedicle screw.DESIGN, TIME AND SETTING: This study, a control experiment, was performed at the Institute of Biomechanics, Sun Yat-sen University, Guangzhou, Guangdong Province, China between January 2006 and December 2007.MATERIALS: The lumbar-sacral spine and pelvis specimens were collected from six freshly cryo-preserved male adult corpses caused by trauma. Iliac screw (8.5mm×100mm), L5 pedicle screw (6.5mm×45mm), and S1 pedicle screw (6.5mm×35mm) were provided by Sofamor Company, USA. MTS 858 Bionix Material Testing System (USA) was also used.METHODS: The lumbar and iliac vertebrae, pelvis from six fresh frozen cadaveric specimens were operated in three different ways of fixation respectively: iliac ala lag screw, L5-S1 pedicle screw rod system, iliac screw and L5 pedicle screw connecting system. Three ways of fixation as mentioned above were compared with the intact group in biomechanical stability.MAIN OUTCOME MEASURES: The mobility of whirl, lateral bending, proneness, and backward stretching among groups.RESULTS: Using iliac screw for the fixation between lumbar-sacral spine and pelvis turned out to be the best in stability. The range of motion (ROM) decreased obviously in each situation. The three-dimensional mobility in the 6.4Nm moment of force was (1.07±0.86)° for whirl, (0.95±0.47)° for lateral bending, (1.22±0.67)° for proneness, and (1.80±0.73)° for backward stretching. There was significant difference between the intact group and the group carried out by iliac screw and L5 pedicle screw for the fixation between lumbar-sacral spine and pelvis (P<0.01).CONCLUSION: The connectible skills using iliac screw and the lumbar-sacral spine pedicle screw possesses the biomechanical advantages of maintaining the stability between lumbar-sacral spine and pelvis.