Pars Plana Ahmed Implantation Combined with 23-gauge Vitrectomy for Refractory Neovascular Glaucoma in Diabetic Retinopathy.
	    		
		   		
		   			
		   		
	    	
    	- Author:
	        		
		        		
		        		
			        		Hoon Seok JEONG
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Dong Heun NAM
			        		
			        		;
		        		
		        		
		        		
			        		Hae Jung PAIK
			        		
			        		;
		        		
		        		
		        		
			        		Dae Yeong LEE
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Original Article
 - Keywords: Diabetic retinopathy; Glaucoma drainage device; Neovascular glaucoma; Vitrectomy
 - MeSH: Adult; Aged; Diabetic Retinopathy/*complications/pathology; Female; Follow-Up Studies; *Glaucoma Drainage Implants; Glaucoma, Neovascular/*complications/pathology/*surgery; Humans; Intraocular Pressure; Male; Middle Aged; Retrospective Studies; Treatment Outcome; Vitrectomy/*methods
 - From:Korean Journal of Ophthalmology 2012;26(2):92-96
 - CountryRepublic of Korea
 - Language:English
 - Abstract: PURPOSE: To evaluate the efficacy and safety of a pars plana Ahmed valve implantation combined with 23-gauge sutureless vitrectomy in the treatment of patients with medically uncontrolled neovascular glaucoma (NVG) in proliferative diabetic retinopathy (PDR). METHODS: The authors retrospectively reviewed the records of 11 consecutive patients with refractory NVG in PDR who underwent a 23-gauge sutureless vitrectomy combined with pars plana placement of an Ahmed valve implant. Control of intraocular pressure (IOP), pre- and postoperative best-corrected visual acuity and the development of intra- and postoperative complications were evaluated during the follow-up. RESULTS: The mean follow-up was 12.2 months (range, 8 to 25 months). Mean preoperative IOP was 35.9 +/- 6.3 mmHg and mean postoperative IOP at the last visit was 13.3 +/- 3.2 mmHg. Control of IOP (8 to 18 mmHg) was achieved in all patients, but 91% (10 of 11 patients) needed antiglaucoma medication (mean number of medications, 1.2 +/- 0.6). Postoperative visual acuity improved in 11 eyes, and the logarithmically to the minimum angle of resolution mean visual acuity in these eyes improved from 1.67 +/- 0.61 to 0.96 +/- 0.67. The complications that occurred were transient hypotony in one case, transitory hypertension in two cases, and postoperative vitreous hemorrhage which spontaneously cleared in two cases. CONCLUSIONS: We suggest the combination of 23-gauge pars plana vitrectomy and Ahmed valve implantation is safe and effective in PDR patients with refractory NVG.
 
            