In vive MR evaluation of the vessel wall shear stress in the common carotid artery
	    		
		   		
	    	
    	
    	
   		
        
        	
        		- VernacularTitle:MR评估在体血管壁切应力的方法探讨
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Binbin SUI
			        		
			        		;
		        		
		        		
		        		
			        		Peiyi GAO
			        		
			        		;
		        		
		        		
		        		
			        		Yan LIN
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Magnetic resonance imaging;
			        		
			        		
			        		
				        		Carotid arteries
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Radiology
	            		
	            		 2008;42(8):854-857
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To apply a non-invasive and feasible method for the quantification of local wall shear stress (WSS) in vivo using magnetic resonance imaging. Methods The fight common carotid artery of a young healthy male volunteer was examined using cine phase-contrast MR sequence. The cross- sectional area, average flow velocity, maximum velocity and flow rate were obtained. Three dimensional paraboloid model was applied to measure WSS value at common carotid artery. Results The mean/peak WSS was (0.75±0.41)N/m2 for the common carotid artery; The mean (range) velocity was (23.4± 12.0) cm/s; The mean (range) luminal vessel area was (32.2±2.9) mm2; The blood flow rate was (7.8±4. 6) ml/s; Conclusion WSS's magnitude, distribution and changes can be determined by MR imaging combining with the three-dimensional paraboloid method.