Effect of PEEP on oxygen utilization coefficient in patients with acute respiratory distress syndrome
	    		
		   		
		   			
		   		
	    	
    	 
    	10.3760/cma.j.issn.1008-6706.2009.01.004
   		
        
        	
        		- VernacularTitle:呼气末正压通气对急性呼吸窘迫综合征患者氧利用率的影响
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Kaixiu HUO
			        		
			        		;
		        		
		        		
		        		
			        		Xiaochuan WANG
			        		
			        		;
		        		
		        		
		        		
			        		Xingguo HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Jiangxia XIE
			        		
			        		;
		        		
		        		
		        		
			        		Ziting QIU
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
        		- Keywords:
        			
	        			
	        				
	        				
			        		
				        		Mechanical ventilation;
			        		
			        		
			        		
				        		Acute respiratory distress syndrome;
			        		
			        		
			        		
				        		Oxygen utilization coefficient
			        		
			        		
	        			
        			
        		
 
        	
            
            
            	- From:
	            		
	            			Chinese Journal of Primary Medicine and Pharmacy
	            		
	            		 2009;16(1):8-9
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	Objective To observe the effects of positive end-expiratory pressure(PEEP) on oxygen utiliza-tion coefficient in patients with acute respiratory distress syndrome(ARDS). Methods 28 ARDS patients with me-chanical ventilation were studied. Catheter of central vein was laid. Increment levels of PEEP(0,5, 10, 15 and 20cmH2O) were applied sequentially. Hemodynamics and oxygen metabolism parameters were measured and calcula-tion of O2 UC [O2 UC = (SaO2 -SvO2.)/SaO2] were carried out respectively. O2 UC in 30 normal subject groups were carried out. Results Arterial oxygen tension(PaO2) increased significantly(P < 0.05) at PEEP 5cmH2O. Oxygen u-tilization coefficient (O2 UC), heart rate(HR) and mean blood pressure (MBP) were not significantly different (P >0.05) at PEEP 10cmH2O. At PEEP 15cmH2 O, O2UC and HR increased significantly (P < 0.05), but M BP reduced obviously(P < 0.05). Conclusions Too high PEEP can result in oxygen utilization coefficient of ARDS patient de-acend furthur, can not really correct oxygen difieiency condition in patients' organization cell. The optimal PEEP should be found, and blood capacity should be appropriately increased.