Late (3years) antomical patency of a No-flow internal mammary artery bypass graft.
	    		
	    			
	    			
		        		
			        		
		        		
			        
		   		
		   		
		   			
		   		
	    	
    	 
    	10.4326/jjcvs.20.656
   		
        
        	
        		- VernacularTitle:冠動脈バイパス術後3年目の造影検査で内胸動脈グラフトが“no flow Patency”を示した一症例
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Noriyoshi SAWABATA
			        		
			        		;
		        		
		        		
		        		
			        		Soichiro KITAMURA
			        		
			        		;
		        		
		        		
		        		
			        		Toshio SEKI
			        		
			        		;
		        		
		        		
		        		
			        		Ryuichi MORITA
			        		
			        		;
		        		
		        		
		        		
			        		Kanji KAWACHI
			        		
			        		;
		        		
		        		
		        		
			        		Tetuji KAWATA
			        		
			        		;
		        		
		        		
		        		
			        		Junichi HASEGAWA
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            
            	- From:Japanese Journal of Cardiovascular Surgery
	            		
	            		 1991;20(4):656-659
	            	
            	
 
            
            
            	- CountryJapan
 
            
            
            	- Language:Japanese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	The left IMA graft to the LAD showed a string sign with no antegrade flow in an asymptomatic 67-year-old man 3 years after the operation. The LAD lesion had regressed from 95% stenosis to less than 50% during this period. Exercise electrocardiographic and thallium 201 myocardial scintigraphic examinations revealed no ischemia in the LAD region. When the LAD was temporarily occluded by a PICA balloon, the anterograde flow from the IMA to the LAD could be demonstrated by angiography. The IMA graft in no flow situation has maintained anatomical patency for 3 years after the operation.