A Case of Surgical Treatment for Pseudoaneurysm 19 Years after Aortic Root Replacement
	    		
	    			
	    			
		        		
			        		
		        		
			        
		   		
		   		
		   			
		   		
	    	
    	 
    	10.4326/jjcvs.37.268
   		
        
        	
        		- VernacularTitle:大動脈基部置換術後19年目の人工血管-人工血管吻合部仮性瘤に対する1手術例
 
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Masashi Kabasawa
			        		
			        		;
		        		
		        		
		        		
			        		Yoshiharu Takahara
			        		
			        		;
		        		
		        		
		        		
			        		Kenji Mogi
			        		
			        		;
		        		
		        		
		        		
			        		Masaharu Hatakeyama
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            
            	- From:Japanese Journal of Cardiovascular Surgery
	            		
	            		 2008;37(5):268-271
	            	
            	
 
            
            
            	- CountryJapan
 
            
            
            	- Language:Japanese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	We report a case of surgical treatment for pseudoaneurysm 19 years after aortic root replacement. The patient was a 57-year-old female who had undergone aortic root replacement (Piehler procedure) in another hospital due to acute Stanford A type aortic dissection in 1988, and was then followed up at another hospital. However, a low density area around the artificial graft was pointed out on computed tomography (CT) in 2001, which increased to 60mm in size by November, 2006. She was then referred to our hospital for a redo operation. Pseudoaneurysm of the anastomosis and mitral regurgitation (MR) was diagnosed by the examination of the CT, angiography, etc., and we performed ascending aorta and aortic arch replacement, and mitral valve replacement (MVR) in April, 2007. A slight hemorrhage were found at the anastomosis of the artificial graft-artificial graft. Deterioration of the artificial graft or deterioration of the suture was suspected as the cause of the slight hemorrhage from the anastomosis a long period after the operation. In this case, loosening of the suture string was revealed, so the latter was more strongly suspected.