Comparison Study of Left Ventricular Function Assessment by 18F-FDG PET, Gated SPECT and 2D-Echocardiography in Patients with Myocardial Infarction.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Fanglan LI
			        		
			        		;
		        		
		        		
		        		
			        		Rui HUANG
			        		
			        		;
		        		
		        		
		        		
			        		Xiaohong OU
			        		
			        		;
		        		
		        		
		        		
			        		Lin LI
			        		
			        		
		        		
		        		
		        		
		        		
		        		
			        		
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Coronary Artery Disease;
				        		
			        		
				        		
					        		Echocardiography;
				        		
			        		
				        		
					        		Fluorodeoxyglucose F18;
				        		
			        		
				        		
					        		Humans;
				        		
			        		
				        		
					        		Linear Models;
				        		
			        		
				        		
					        		Myocardial Infarction;
				        		
			        		
				        		
					        		diagnosis;
				        		
			        		
				        		
					        		Positron-Emission Tomography;
				        		
			        		
				        		
					        		Regression Analysis;
				        		
			        		
				        		
					        		Stroke Volume;
				        		
			        		
				        		
					        		Tomography, Emission-Computed, Single-Photon;
				        		
			        		
				        		
					        		Ventricular Function, Left
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:
	            		
	            			Journal of Biomedical Engineering
	            		
	            		 2015;32(5):1090-1095
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	The aim of this study is to analyze the concordance between EDV, ESV and LVEF values derived from 18F-FDG PET, GSPECT and ECHO in patients with myocardial infarction. Sixty-four patients with coronary artery disease (CAD) and myocardial infarction were enrolled in the study. Each patient underwent at least two of the above mentioned studies within 2 weeks. LVEF, EDV and ESV values were analyzed with dedicated software. Statistical evaluation of correlation and agreement was carried out EDV was overestimated by 18F-FDG PET compared with GSPECT [(137.98 ± 61.71) mL and (125.35 ± 59.34) mL]; ESV was overestimated by 18F-FDG PET (85.89 ± 55.21) mL and GSPECT (82.39 ± 55.56) mL compared with ECHO (68.22 ± 41.37) mL; EF was overestimated by 18F-FDG PET (41.96% ± 15.08%) and ECHO (52.18% ± 13.87%) compared with GSPECT (39.75% ± 15.64%), and EF was also overestimated by 18F-FDG PET compared with GSPECT. The results of linear regression analysis showed good correlation between EDV, ESV and LVEF values derived from 18F-FDG PET, GSPECT and ECHO (r = 0.643-0.873, P = 0.000). Bland-Altman analysis indicated that 18F-FDG PET correlated well with ECHO in the Left ventricular function parameters. While GSPECT correlated well with 18F-FDG PET in ESV, GSPECT had good correlation with Echo in respect of EDV and EF; whereas GSPECT had poor correlation with PET/ECHO in the remaining left ventricular function parameters. Therefore, the clinical physicians should decide whether they would use the method according to the patients' situation and diagnostic requirements.