Fluorescence spectra and test application study on the interaction of fluorescein and bovine serum albumin.
	    		
		   		
	    	
    	
    	
   		
        
        	
        	
        	
        		- Author:
	        		
		        		
		        		
			        		Xun HUANG
			        		
			        		
			        		
			        			1
			        			,
			        		
			        			2
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Ai'ming SUN
			        		
			        		;
		        		
		        		
		        		
			        		Xueqin DING
			        		
			        		;
		        		
		        		
		        		
			        		Xiucheng XU
			        		
			        		;
		        		
		        		
		        		
			        		Luyan FANG
			        		
			        		
		        		
		        		
		        		
		        		
		        			
			        		
			        		Author Information
			        		
		        		
		        		
			        		
			        		
			        			1. Department of Biomedical Analysis, Analysis and Testing Center, Sichuan University, Chengdu 610041, China. huangfxcz@
			        		
			        			2. com
			        		
		        		
	        		
        		 
        	
        	
        	
        		- Publication Type:Journal Article
 
        	
        	
            
            	- MeSH:
            	
	        			
	        				
	        				
				        		
					        		Animals;
				        		
			        		
				        		
					        		Cattle;
				        		
			        		
				        		
					        		Drug Interactions;
				        		
			        		
				        		
					        		Fluorescein;
				        		
			        		
				        		
					        		chemistry;
				        		
			        		
				        		
					        		Serum Albumin, Bovine;
				        		
			        		
				        		
					        		analysis;
				        		
			        		
				        		
					        		Spectrometry, Fluorescence;
				        		
			        		
				        		
					        		methods
				        		
			        		
	        			
	        			
            	
            	
 
            
            
            	- From:
	            		
	            			Journal of Biomedical Engineering
	            		
	            		 2006;23(6):1325-1327
	            	
            	
 
            
            
            	- CountryChina
 
            
            
            	- Language:Chinese
 
            
            
            	- 
		        	Abstract:
			       	
			       		
				        
				        	A fluorescence method is found for determination of bovine serum albumin (BSA). The method is based on the interaction of fluorescein with BSA to form a complex in Tris-HCl buffer of pH 2.2. The complex exitation wavelength is 467 nm, the emission wavelength is 515 nm. The linear measurement rang is between 1.8-500 mg/L for BSA, F = 26.776 C + 2.8082, r = 0.9999. This method is sensitive,steady,and low cost for determination of BSA.