Emergence application of colonoscopic placement of self-expandable metal stent without fluoroscopic monitoring.
- Author:
	        		
		        		
		        		
			        		Zheng LOU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		En-da YU
			        		
			        		;
		        		
		        		
		        		
			        		Wei ZHANG
			        		
			        		;
		        		
		        		
		        		
			        		Lian-jie LIU
			        		
			        		;
		        		
		        		
		        		
			        		Li-qiang HAO
			        		
			        		;
		        		
		        		
		        		
			        		Han-tao WANG
			        		
			        		;
		        		
		        		
		        		
			        		Rong-gui MENG
			        		
			        		;
		        		
		        		
		        		
			        		Chuan-gang FU
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Journal Article
 - MeSH: Adult; Aged; Aged, 80 and over; Colonoscopy; Colorectal Neoplasms; complications; Female; Humans; Intestinal Obstruction; etiology; therapy; Male; Middle Aged; Retrospective Studies; Stents
 - From: Chinese Journal of Gastrointestinal Surgery 2013;16(4):363-366
 - CountryChina
 - Language:Chinese
 - 
		        	Abstract:
			       	
			       		
				        
				        	
OBJECTIVETo evaluate the efficacy and safety of colonoscopy-guided placement of self-expandable metallic stent without fluoroscopic monitoring in the emergence management for acute malignant colorectal obstruction.
METHODSClinical data of 42 patients (24 males and 18 females with a mean age of 64.3 years) undergoing colonoscopy-guided placement of self-expandable metallic stents without fluoroscopic monitoring for acute malignant colorectal obstruction between January 2010 and June 2012 were reviewed retrospectively.
RESULTSThe obstruction was located in the rectum (n=19), sigmoid (n=9), descending colon (n=8), splenic flexure (n=1), hepatic flexure (n=3), and ascending colon (n=2). Technical success was achieved in all the 42 patients (100%). The mean time of operation was (11.8±10.4) min (range 1.1-51.0 min). No serious procedure-related complication occurred. Minor bleeding occurred in 3 cases (7.1%). One patient died on the second day after surgery because of heart failure.
CONCLUSIONSColonoscopy-guided placement of self-expandable metallic stents without fluoroscopic monitoring in emergence management for acute malignant colorectal obstruction is effective and safe with shorter operative time.
 
            