Clinical value of double respiratory navigator-gated high-resolution black-blood coronary artery wall magnetic resonance imaging.
	    		
		   		
		   			
		   		
	    	
    	- Author:
	        		
		        		
		        		
			        		Hai-yue JU
			        		
			        		
			        		
			        			1
			        			
			        		
			        		
			        		
			        		
			        		;
		        		
		        		
		        		
			        		Li YANG
			        		
			        		;
		        		
		        		
		        		
			        		Liu-quan CHENG
			        		
			        		;
		        		
		        		
		        		
			        		Zu-long CAI
			        		
			        		
		        		
		        		
		        		
			        		
			        		Author Information
			        		
 - Publication Type:Journal Article
 - MeSH: Adult; Coronary Vessels; anatomy & histology; Female; Humans; Magnetic Resonance Imaging; methods; Male; Middle Aged; Young Adult
 - From: Acta Academiae Medicinae Sinicae 2013;35(3):305-310
 - CountryChina
 - Language:Chinese
 - 
		        	Abstract:
			       	
			       		
				        
				        	
OBJECTIVETo explore the value of phase ordering with automatic window selection(PAWS)and simultaneous multiple volume(SMV)algorithm double respiratory navigator-gated two-dimensional(2DNAV)dual inversion recovery(DIR)fast spin echo(FSE)high-resolution black-blood coronary artery wall magnetic resonance imaging(MRI)and evaluate its advantages and limitations.
METHODSPAWS and SMV 2DNAV DIR FSE high-resolution black-blood MRI was performed in 21 healthy volunteers. The images were evaluated qualitatively by using four grades(grade 0can not evaluate;grade 1bad;grade 2good;grade 3perfect). Images defined as grade 0 and grade 1 were excluded and those defined as grade 2 and 3 were evaluated further. Thickness of proximal(or middle)segment of right coronary artery(RCA)and left anterior descending branch(LAD)were measured. The difference of wall thickness was analyzed by using two-tailed independent sample t-test. P values of less than 0.05 were considered statistically significant.
RESULTSAmong the 38 slice images,31 slices(RCA13 slices,LAD18 slices;grade 214 slices,grade 317 slices)were obtained for further evaluation. The mean thickness of RCA and LAD was(0.94±0.16)and(0.89±0.15)mm,respectively,and the difference was not significant(t=-0.790,P>0.05).
CONCLUSIONPAWS and SMV algorithm 2DNAV DIR FSE high-resolution black-blood MRI has certain clinical value for coronary artery wall imaging.
 
            